GenScript cPass™ SARS-CoV-2 Neutralization Antibody Kit

Catalog No. L00847

GenScript’s cPass™ SARS-CoV-2 Neutralization Antibody Kit quickly and accurately detects and measures neutralization response in a sample against the SARS-CoV-2 virus.

cPass-EUA-01-ver22

60 mins

to measure functional neutralizing antibodies (NAbs)

99.4%

Specificity


93.8%

Sensitivity


96 Tests

Per Kit


The sVNT test is faster, easier, more scalable, and readily automatable compared to the traditional neutralizing antibody tests, such as virus neutralization test (VNT), pseudo-virus neutralization test (pVNT), and plaque reduction neutralization test (PRNT).

The Benefits

icon5

FDA EUA
Approved

icon2

High Sensitivity & Specificity

icon1

Safe and
Scalable

icon4

TAT: 24 hours
Or Less

Reducing the Chromogenic Reaction

 

The kit contains two key components: the Horseradish peroxidase (HRP) conjugated recombinant SARS-CoV-2 RBD fragment (HRP-RBD) and the human ACE2 receptor protein (hACE2).

 

The cPass SARS-CoV-2 Neutralizing Antibody Kit is a blocking ELISA detection tool, which mimics the virus neutralization process. The test uses the interaction between viral protein-receptor protein to mimic the virus infection of a live cell, which is monitored by a chromogenic reaction. When there are neutralizing antibodies in the patient sera, they will block the specific protein-protein interaction and hence reducing the chromogenic reaction, mimicking the virus neutralization process.

 

What's Included?

Part Number: S1-80
Quantity: 1 plate

Part Number: S1-10
Quantity: 1 vial (0.05 mL)

Part Number: S1-11
Quantity: 1 vial (0.05 mL)

Part Number: S1-30
Quantity: 1 vial (0.02 mL)

Part Number: S1-90
Quantity: 1 bottle (10 mL)

Part Number: S1-60
Quantity: 1 bottle (30 mL)

Part Number: S1-70
Quantity: 1 bottle (40 mL)

Part Number: S1-40
Quantity: 1 bottle (12 mL)

Part Number: S1-50
Quantity: 1 bottle (6 mL)

Part Number: N/A
Quantity: 2 pieces

cPass-EUA-01-ver22

How To Use

96 well ELISA format test with ACE2 protein attached to the plate and HRP-labeled RBD used for detection.

The test can be used with serum and plasma samples.

Positive and negative controls are included in the kit.

 

Other instruments required but not included with the test:
•Single or dual wavelength microplate reader with 450 nm filter. Read the Operator’s Manual or contact the instrument manufacturer to establish linearity performance specifications of the reader.
•Automated microplate washer to wash the plate
•Deionized or distilled water to dilute 20× Wash Solution
•Graduated cylinder to prepare Wash Solution
•Plastic container to store Wash Solution
•Tubes to aliquot and dilute samples
•10 μL, 200 μL and 1000 μL precision pipettes
•10 μL, 200 μL and 1000 μL pipette tips
•Multichannel pipettes
•Disposable reagent reservoir
•Paper towels
•Laboratory timer
•Refrigerator to store samples and kit components
•Centrifuge
•37 ºC Incubator

Find out if GenScript is right for your lab.